Fresh Water Generator

Converting Seawater to Freshwater on a Ship: Fresh Water Generator Explained


Fresh water generator, one of the important machinery on board a ship, is something that cannot be done without. Fresh water produced from fresh water generator is used for drinking, cooking, washing and even running other important machinery which use fresh water as a cooling medium.

Fresh water is generally produced on board using the evaporation method. There are two things that are available in plenty on ship to produce fresh water –Seawater and heat. Thus fresh water is produced by evaporating sea water using heat from any of the heat source. The evaporated sea water is then again cooled by the sea water and the cycle repeats.

Generally the heat source available is taken from the main engine jacket water, which is used for cooling the main engine components such as cylinder head, liner etc. The temperature available from this jacket water is about 70 deg. centigrade. But at this temperature the evaporation of water is not possible as we all know that the evaporation of water takes place at 100 deg centigrade under atmospheric pressure.

Thus in order to produce fresh water at 70 degrees we need to reduce the atmospheric pressure, which is done by creating a vacuum inside the chamber where the evaporation is taking place. Also, as a result of the vacuum the cooling of the evaporated sea water will also take place at lower temperature. This cooled water is collected and transferred to the tank.

Nowadays, reverse osmosis is one of the methods which are used on board for generating fresh water. Generally this is used on passenger vessels wherein there is a large requirement of fresh water production. However, in merchant ships the evaporation method is used as reverse osmosis is costly and includes large maintenance cost for membrane.

Fresh Water Generator Arrangement

The main body of a fresh water generator on the ship consists of a large cylindrical body with two compartments. One of the compartments is the condenser and the other is the evaporator. The fresh water generator also consists of an educator which helps in generating the required vacuum. The fresh water pump and ejector pump helps in transfer of water to and from the fresh water generator.

Starting the Fresh Water Generator

1. Before starting the fresh water generator we have to check that the ship is not in congested water, canals and is 20 nautical miles away from the shore. This is done because near the shore the effluents from factories and sewage are discharged into the sea can get into the fresh water generator.

2. Check whether engine is running above 50 rpm, the reason for this is that at low rpm the temperature of jacket water which is around 60 degrees and not sufficient for evaporation of water.

3. Check the drain valve present at the bottom of the generator is in close position.

4. Now open suction and discharge valves of the sea water pump which will provide water for evaporation, cooling and to the eductor for creating vacuum.

5. Open the sea water discharge valve from where the water is sent back to the sea after circulating inside the fresh water generator.

6. Close the vacuum valve situated on top of the generator.

7. Now start the sea water pump and check the pressure of the pump. The pressure is generally 3-4 bars.

8. Wait for the vacuum to build up. Vacuum should be at least 90% which can be seen on the gauge present on the generator. Generally the time taken for the generation of vacuum is about 10 minutes.

9. When vacuum is achieved open the valve for feed water treatment, this is to prevent scale formation inside the plates.

10. Now open hot water (jacket water) inlet and outlet valves slowly to about half. Always open the outlet valve first and then inlet valve. Slowly start to increase the opening of the valves to full open.

11. Now we can see that the boiling temperature starts increasing and the vacuum starts dropping.

12. The vacuum drop to about 85% which is an indication that evaporation is started.

13. Open the valve from fresh water pump to drain.

14. Switch on the salinometer if it has to be started manually. Generally it is on auto start.

15. Now start fresh water pump and taste the water coming out of the drain.

16. When fresh water starts producing it is seen that the boiling temperature drops again slightly and vacuum comes back to the normal value.

17. Check the water coming out of the salinometer is not salty and also check the reading of the salinometer. This is done to see if the salinometer is working properly or not and to prevent the whole fresh water from getting contaminated with salt water. The value of salinometer is kept below 10ppm.

18. After checking the taste of the water coming out of the salinometer, open valve for tank from the pump and close drain valve.

Stopping the Fresh water Generator


1. Close the jacket water inlet valves. Generally inlet is closed first and then the outlet valve.

2. Close the valve for feed water treatment.

3. Stop fresh water pump.

4. Switch off the salinometer.

5. Stop sea water pump (also known as ejector pump).

6. Open vacuum valve.

7. Close sea water suction valve and overboard valve. This is generally not required as they are non- return valves. However, in case of valve leaking or damage, these valves are to be closed without fail.

Comments

  1. Hello all,

    The freshwater generator should include a feature to monitor the salinity of the processed water. If the salinity exceeds a specified level, usually between one and ten parts per million, the freshwater generator will automatically return the water to the feed line and put it through the cycle again. Thanks a lot!

    Cleaning Heat Exchangers

    ReplyDelete
  2. Hello guys..

    Fresh water generator is to manufacture fresh water by using sea water. It's installed and used in ship and island. It's divided into the low-pressure evaporation type and inverse osmotic pressure type.
    Most of commercial ships use the low-pressure evaporation type to manufacture fresh water using steam.

    Thanks for giving such valuable inflammations..
    Fresh Water Generator

    ReplyDelete
  3. Good day sir..
    Is it good to maintain the water in the evaporator as high as possible and what is the fresh water generator output if the sea water temperature drops while the ship is in a very cold area

    ReplyDelete

Post a Comment

Popular posts from this blog

Shaftline 1.rudder stock, 2.rudder, 3.propeller bonnet, 4.propeller, 5.stern frame, 6.stern tube sealing, 7.stern tube bearings 8.stern tube, 9.propeller shaft, tail shaft, 10.plummer Mock, pillow block, shaft block, 11.intermediate shaft, 12.thrust shafts 13.flywheel, 14.crankshaft, shaft alley, shaft tunnel,

Maintenance ONBOARD

  Types of Maintenance Procedures 1)   Preventive or Scheduled Maintenance System It is famously known as the PMS or Planned Maintenance System. In this type of system the maintenance is carried out as per the running hours like 4000 hrs, 8000 hrs etc., or by the calendar intervals like 6 monthly, yearly etc. of the machinery. The maintenance is carried out irrespective of the condition of the machinery. The parts have to be replaced if it is written in the schedule, even if they can be still used. 2)  Corrective or Breakdown Maintenance In this system, maintenance is carried out when the machinery breaks down. This is the reason it is known as breakdown maintenance. This is not a suitable and good method as situations may occur wherein the machinery is required in an emergency. The only advantage of this system is that the working of machinery parts is used to its full life or until it breaks. This system might get costly as during breakdown several other parts may also get damaged. 3